Safety Precautions
(Read first before proceeding)
Warning
Before connecting and operating the Sapphire
®
Plus, read all safety instructions. When used properly and with
normal precautions, the Sapphire Plus is a safe and effective multi-purpose light system. However, the Sapphire
Plus is a source of high electrical voltage, intense light, and heat. This product must only be used as indicated in
this manual.
Before connecting the Sapphire Plus to the mains (the AC wall outlet), verify that the voltage to be applied is
within the range of that specified on the identification label on the backside of the instrument. If you have any
questions concerning the proper voltage, call the factory for clarification.
To avoid risk of electric shock, disconnect the power cord before opening the lamp access door or removing the
product cover. All repairs other than lamp replacement must be made by a factory authorized representative. Do
not touch or probe other electronic components inside the product.
High-intensity light can be harmful to the eyes. When the system is in use, the patient, operator, and assistant(s)
must wear protective eyewear. Caution should be used to avoid accidentally starting the light outside of the
mouth. To avoid possible injury, never look directly into the end of the light guide or directly into the light output
on the front panel (even with protective eyewear). Never shine the light into the eyes.
High-intensity dental lights should not be used by operators or on patients who may be photo-sensitive.
Do not expose soft oral tissues directly to the tip of the light at close proximity.
Only use the light guide supplied with the Sapphire Plus. Other light guides may not be effective and may
damage the light. Do not cause excessive bending in the light guide. Do not drop the light guide or tip. Do
not autoclave the light shield provided with the unit. Do not autoclave the light guide. Removable curing tip is
autoclavable; Laser tip is not autoclavable.
Do not use abrasives or liquid chemicals to clean the tip or the light housing.
The fan at the rear of the light provides cooling when the system is on. Obstructing the air flow will cause heat
buildup and will damage the system.
Disconnect the Sapphire Plus power cord from the power outlet and contact the factory for service instructions
if the light has been exposed to liquid spills, dropped or otherwise damaged (including the power cord), or
otherwise malfunctions.
Do not use in the presence of flammable materials.
Do not look directly into the end of the laser tip.
Caution: US Federal Law restricts the use of this device to use by or on the order of a dentist